Symphony Choir 2-5 Zone DC Inverter Mini Split (59)2


AboutFeaturesSpecifications 30000-42000 Btu/hSpecifications 48000-60000 BtuDownloads

YMGI
Symphony CHOIR 59 Series

Multiple-Zone (59)2 Series 1-5 Zone Mini-split

YMGI DC INVERTER CHOIR
Multi Zone-Outdoor Units

The CHOIR outdoor condensing unit has a 16 SEER rating, with capacities from 30k to 60k Btu/h and capable of heating and cooling 1 to 5 zones. The CHOIR requires 208-230 volt, 1 phase, 60Hz power. R410-A refrigerant is used to dispense heat into ambient air in the summer, while absorbing heat from ambient air in the winter. The compact design allows for ground installation, or mounting on a wall, under a deck or even on a balcony.

A Smart Heating And Cooling Solution

Mini-split systems are a great solution for both new construction and retrofit or remodeling jobs. They are easy to install, and don’t require tying in to existing duct work. They’re also ideal for a modern heating and cooling solution in or older houses that were built with hot water heat, radiant heat, or space heaters.

Mini-splits are a great choice for room additions and other structures such as sun rooms, garages, sheds and pool houses. Heat and cool rooms and structures that cannot be connected to the existing central air conditioning system, or where extending or installing duct work would be time consuming, costly, or impossible.

How Mini-split Systems Work:

The Differences between Central Air and Mini-split Systems
All air conditioning systems consist of an outdoor condensing unit and an indoor evaporator unit. The difference between a mini-split and central system is that the evaporator unit of the central system is installed in the basement or attic and uses metal or fiberglass ductwork to deliver warm or cool air to various rooms in your home. A central system requires space inside the walls between the joists for the duct work, plus floor/wall/ ceiling space to install the registers. Duct work can be a haven for dust, germs, mold, bacteria, and insects.

With a ductless mini-split system, the indoor unit is mounted in the room you want to heat or cool. The outdoor and indoor units are connected with copper refrigerant pipes, and power and communication wires, that are wrapped tightly, insulated, and passed through a small 3” opening in the wall. Installation is fast and easy.

The mini-split’s compressor (found in the outdoor condensing unit) pumps refrigerant through the condensing coils and the metering device to the indoor unit where a fan blows across the coil to cool the room. In heating mode, the unit absorbs heat from the outside air and moves it indoors to heat the room. In most climates, this provides efficient heating and cooling, keeping you comfortable all year long.

Most central system outdoor units are up-flow, which means the condenser fan is pointed upwards. Because of this, the outdoor units need more installation room. A mini-split system’s outdoor unit is horizontal flow, with the fan pointed sideways. Because it requires less room, a mini-split can be placed where installation of a central air system would not be possible. A mini-split can be installed on a concrete pad, a balcony or below a deck, making them ideal for metropolitan areas, where space between buildings can be very tight.

Maximum Comfort, Minimum Cost

A conventional forced air cooling or heating system uses an “on and off” cycle. When a conventional system starts running, it runs at its top speed, consuming the maximum amount of energy in order to reach the desired temperature. The system then cycles on and of to maintain the set temperature. The continual starting and stopping of the major components in a conventional air conditioning system reduces the life span of the compressor and other components.

YMGI mini-splits use a DC Inverter to convert alternating current (AC) to Direct Current (DC), modulate pulse width, and then direct the inverted current back to alternating current (AC) at the optimum frequency, giving precise control over the operating speeds of the electric motors and compressor. Our Symphony Series Mini-split DC Inverter system, allow your system to start slowly and smoothly, and then accelerate to higher speeds to quickly bring the room to the desired temperature. Once the set temperature is reached, the system slows and adjusts itself to counter the heat gain or loss of the room, maintaining a more consistent temperature. Delivering maximum comfort at minimum cost.

Easy to Operate and Easy To Live With

Every YMGI mini-split indoor unit comes with a remote control, that lets you select the thermal mode, desired temperature, fan speed, and oscillation of the air louvers, allowing you to customize your comfort. The remote lets you program the start and stop time. YMGI mini-split indoor units use oscillating louvers to evenly distribute conditioned air throughout an entire room. The outdoor units feature quiet operation, horizontal venting and take up less space then a conventional central air condenser.

Products Perfect for Any Decor

YMGI (59)4 systems offers 4 different indoor units. Our wall mounted EW is the most popular. The EC ceiling cassette is designed to be mounted to the ceiling. The EF recessed fan coil can be mounted above the ceiling and attached to a short piece of duct work to a standard floor, wall or ceiling register. The EU has the flexibility of floor or ceiling installation. YMGI has indoor units that suit your needs and your taste.

High Efficiency
YMGI multi-zone mini split systems, with ratings of 16 SEER, are ETL listed in both the U.S. and Canada, and certified by AHRI and ENERGY STAR®.

Intelligent Defrosting
YMGI defrosting is controlled by a microcomputer processor and ensure worry-free, heat pump performance in mild and cold weather. This unique ON-DEMAND defrosting design improves heating efficiency, thermal performance and keeps your room comfortable throughout the winter.

U-TOUCH Remote Control
YMGI’s U-TOUCH remote lets you control every feature and function of your Indoor Unit, from anywhere in the room. While other mini-split systems place their indoor air temperature sensor behind the grille of an indoor unit, YMGI’s sensor is built into the remote. It measures the temperature where people are located, not the wall or ceiling unit. Accurate temperature control for personal comfort.

YMGI Technology

  • DC Inverter Technology – Continuously Adjusting for Profound Performance
    Unlike conventional systems that repeatedly cycle between on and off, YMGI Symphony SOLO DC Inverter systems monitor room temperature and continuously adjust compressor speed up or down to provide precise temperature and humidity control. The incoming electrical power has a fixed frequency of 60 Hertz. DC Inverter systems convert alternating current (AC) to Direct Current (DC), modulate the pulse width, and then convert the inverted current back to alternating current (AC) at the optimum voltage and frequency, allowing the system precisely generate the temperature needed, and maintaining room temperature within a very narrow range, while consuming substantially less energy.
  • Optimized System Design
    Components are both individually and systematically optimized to ensure SOLO systems work in wide ranges of applications, and deliver the right amount of heating or cooling when you need it, and with maximum efficiency.
  • Low Ambient Temperature Heating & Cooling
    When outdoor temperatures drop, heat pump capacity and efficiency are lower. In low ambient temperatures, YMGI’s DC Inverter technology operates at higher efficiency than many other systems available on the market. The powerful heating system ensures you stay warm, even in extreme cold weather. YMGI’s DC Inverter technology and special control logic also make cooling in low ambient temperature ranges a reality.
  • Compressor Crank Case Heater
    This component helps heat up the compressor when the outdoor ambient temperature is low, so the compressor can have a smooth, easy start, especially in extreme cold weather.
  • Soft Start
    The compressor starts at a lower voltage and frequency and accelerates, for a smooth and soft start. This reduces energy consumption of the outdoor unit by approximately 30% compared to conventional HVAC systems. This also reduces electrical circuit load when more than one electrical device is used.
  • De-Ice Base Pan Heater
    This component prevents damage to your unit’s fan blade, coil, compressor, and other components. Automatically activated when outdoor temperatures go below freezing, when ice could form in the base pan.
  • Over-Current, Over-Heat & Over-Pressure Protection
    Built-in protection for over-current, over-heat and over-pressure, ensure safe operation and component longevity.
  • Adaptive Smart Control
    The adaptive smart control fuzzy logic enables responsive and precise control over the compressor frequency, voltage, fan speed and valve opening size. This ensures rapid, precise and safe adjustments; delivering the exact amount of warm or cool air with minimum energy consumption.

Comfort & Convenience

  • Auto Mode
    By continuously sensing and comparing the set temperature to the room temperature, this feature switches between heating and cooling modes automatically delivering the exact amount of warm or cool air needed to ensure maximum comfort.
  • Fast Turbo Heating and Cooling
    This function boosts cooling or heating capacities at high compressor speed and fan speed. Rooms reach set temperatures as rapidly as possible.
  • Air Swing
    Motorized louvers that pivot vertically or horizontally, direct air throughout a room, maintaining an even temperature, and eliminating hot or cold spots. The louver motor can also be turned off, so that you can direct air flow to a specific spot. And it can all be adjusted using the remote control.
  • Hot Start-Up
    When heating operation is selected, or when the system transitions from cooling to heating, the indoor fan motor doesn’t immediately start. This prevents cold air from being blown into an already cold room. When the indoor unit coil and pipes are heated, the fan engages and circulates warm air.
  • Sleep Mode
    With the Sleep Mode on, the system will adjust the room target temperature to slowly rise when cooling or fall when heating. Saving energy, and allowing you to sleep comfortably while preventing sudden changes in the room’s temperature.
  • 24-Hour On/Off Timer
    Set your indoor unit to heat or cool any time of day.
  • Memory and Auto Restart
    If your unit should lose power, YMGI systems remember the operation mode, airflow, and temperature settings and continue normal operation once power is restored.
  • Self-Diagnosing
    Error codes are shown either on the LCD display of the indoor unit, or LED lights on the outdoor control boards. Should your system have a problem, it can be diagnosed easily and accurately by an HVAC professional, helping to quickly resolve the issue.
  • Digital Display On/Off
    Our easy to read LCD display can be turned on or off with the remote control. This feature allows a room to remain dark at night, or you can turn the digital display on and use the display as a night-light.

Safety Systems

  • Low Pressure / Refrigerant Leaking Sensor
  • Compressor Discharge Temperature Sensor
  • Outdoor Coil Temperature Sensor
  • Outdoor Ambient Temperature Sensor
  • Indoor Coil Temperature Sensor
  • Indoor Air Temperature Sensor
  • Built-in Over-Current Fuse at Outdoor Unit
  • Built-in Over-Current Fuse at Indoor Unit
  • Optional De-Ice Heater in Outdoor Unit Pan
Outdoor Unit Models WMMS-30CH-V2B(59)2
(1 to 2 zones)
WMMS-36CH-V2B(59)2
(1 to 3 zones)
WMMS-42CH-V2B(59)2
(1 to 4 zones )
Power Supply 208-230/1/60 208-230/1/60 208-230/1/60
Cooling Capacity* (Btu/h) Max. IDU Cap. Total 2) 30,000 36,000 48,000
Rated 1) 18,000 24,000 28,000
Min 7,200 10,000 10,000
Total Power Input in Cooling Mode* (W) Max. 2300 3300 4500
Rated 1550 2250 2600
Min. 650 800 900
SEER Btu/h/W 16.0 16.0 16.0
HSPF Btu/h/W 8.2 8.2 8.2
Heating Capacity* (Btu/h) Max. IDU Cap. Total 2) 32,000 38,000 50,000
Rated 1) 19,000 29,500 31,000
Min. 6,500 9,000 9,000
Total Power Input in Heating Mode* Max. 2400 3000 3500
Rated 1750 2500 2920
Min. 650 800 900
Liquid Valve Size 2 x 1/4″ 3 x 1/4″ 4 x 1/4″
Gas Valve Size 2 x 3/8″ 3 x 3/8″ 4 x 3/8″
Compressor Manufacturer/trademark Sanyo / Mitsubishi / Others Sanyo / Mitsubishi / Others Sanyo / Mitsubishi / Others
Compressor Oil / FV50S / / FV50S / / FV50S /
L.R.A. (A) 27 45 45
Compressor RLA (A) 8.4 9.7 9.7
Compressor Power Input (W) 1245 2200 2200
MCA (A) 15 20 20-All IDUs EW / 30-All IDUs EC or EU
Fuse or Circuit Breaker (HVAC Type) 30 30 30-All IDUs EW / 40-All IDUs EC or EU
Throttling Method Electronic Expansion Valve Electronic Expansion Valve Electronic Expansion Valve
Starting Method Transducer starting Transducer starting Transducer starting
Recommended Working Ambient Temp Ranges (F) AC: 20 to 115 HP: 5 to 75 AC: 20 to 115 HP: 5 to 75 AC: 20 to 115 HP: 5 to 75
Condenser Aluminum fin-copper tube Aluminum fin-copper tube Aluminum fin-copper tube
Output of Fan Motor (W) 60 60 60
Fan Motor RLA (A) 0.65 0.65 0.65
Fan Motor Capacitor (uF) 3 3.5 3.5
Air Flow Rate of Outdoor Unit / / /
Fan Type-Piece Axial fan 1 Axial fan 1 Axial fan 1
Fan Diameter (Inches) 18.1 18.1 18.1
Defrosting Method Auto Defrost Auto Defrost Auto Defrost
Climate Type T1 T1 T1
Isolation I I I
Moisture Protection IP24 IP24 IP24
Max. Operating Pressure at High Side (PSI) 550 550 550
Max. Operating Pressure at Low Side (PSI) 175 175 175
Sound Pressure Level dB (A) (H/L) 56/54 56/54 56/54
Sound Power Level dB (A) (H/L) 66/64 66/64 66/64
Dimensions of Outdoor Unit (W x H x D) (Inches) 33.3 x 27.0 x 11.8 37.4 X 27.5 X 15.5 37.2 X 27.6 X 15.75
Dimensions of Package (W x H x D) (Inches) 39.1 x 29.5 x 16.9 40.6 X 29.5 X 16.5 40.5 X 29.5 X 18.0
Net Weight /Gross Weight (LBs) 115 / 126 150 / 161 165 / 176
Refrigerant /Factory Pre-Charge for 25′ (LBs) R410A / 2.97 R410A / 4.84 R410A / 4.84

 

Outdoor Unit Models WMMS-48CH-V2B(59)2
(1 to 4 zones)
WMMS-60CH-V2B(59) 2
(1 to 5 zones)
Power Supply 208-230/1/60 208-230/1/60
Cooling Capacity* (Btu/h) Max. IDU Cap. Total 2) 57,000 72,000
Rated 1) 30,000 42,000
Min 10,000 12,000
Total Power Input in Cooling Mode* (W) Max. 4500 5100
Rated 2600 3950
Min. 1000 1200
SEER 16.0 16.0
HSPF 8.2 8.2
Heating Capacity* (Btu/h) Max. IDU Cap. Total 2) 59,000 74,000
Rated 1) 33,000 46,000
Min. 9,000 10,000
Total Power Input in Heating Mode* Max. 3500 4800
Rated 2920 4400
Min. 1000 1200
Liquid Valve Size 4 x 1/4″ 4 x 1/4″ + 3/8″
Gas Valve Size 4 x 3/8″ 2×3/8″+2×1/2″+5/8″
Compressor Manufacturer/trademark Sanyo / Mitsubishi / Others Sanyo / Mitsubishi / Others
Compressor Oil / FV50S / / FV50S /
L.R.A. (A) 45 55
Compressor RLA (A) 10 13
Compressor Power Input (W) 2200 3000
MCA (A) 30-All IDUs EW / 40-All IDUs EC or EU 40
Fuse or Circuit Breaker (HVAC Type) 40-All IDUs EW / 50-All IDUs EC or EU 40-All IDUs EW / 50-All IDUs EC or EU
Throttling Method Electronic Expansion Valve Electronic Expansion Valve
Starting Method Transducer starting Transducer starting
Recommended Working Ambient Temp Ranges (F) AC: 20 to 115 HP: 5 to 75 AC: 20 to 115 HP: 5 to 75
Condenser Aluminum fin-copper tube Aluminum fin-copper tube
Output of Fan Motor (W) 60 140
Fan Motor RLA (A) 0.65 1.1
Fan Motor Capacitor (uF) 3.5 6
Air Flow Rate of Outdoor Unit / /
Fan Type-Piece Axial fan 1 Axial fan 1
Fan Diameter (Inches) 18.1 22.5
Defrosting Method Auto Defrost Auto Defrost
Climate Type T1 T1
Isolation I I
Moisture Protection IP24 IP24
Max. Operating Pressure at High Side (PSI) 550 550
Max. Operating Pressure at Low Side (PSI) 175 175
Sound Pressure Level dB (A) (H/L) 56/54 56/54
Sound Power Level dB (A) (H/L) 66/64 66/64
Dimensions of Outdoor Unit (W x H x D) (Inches) 37.4 X 27.5 X 15.5 42.25 X 43.5 X 17.5
Dimensions of Package (W x H x D) (Inches) 40.6 X 29.5 X 16.5 46.0 X 48.6 X 19.4
Net Weight /Gross Weight (LBs) 165 / 176 225 / 248
Refrigerant /Factory Pre-Charge for 25′ (LBs) R410A / 4.84 R410A / 10.6
Loading Quantity 20′ Container 80 50
40′ Container 170 100
40′ High Cube Container 170 100