High Efficiency
HARMONY ELITE systems have been tested up to 13 SEER, higher than any other PTAC systems available.

Independent Dehumidification
Humidity levels are prioritized over temperature levels in a room, allowing the room to heat and cool more quickly and efficiently.

YMGI’s WMMP Systems

Better Extreme Weather Performance
While most PTHPs have to rely on an electric heater in ambient temperatures below 35°F, the HARMONY ELITE heat pump will work down to 14°F.

Easy installation
HARMONY Elite WMMP system is completely self-contained in a 37” x 24” x 10” cabinet. Two 8” holes for intake and exhaust need to be cut through the wall, and the system is hung on a mounting bracket over them. We include an easy to use template so you know precisely where to drill and cut. Installation really is that easy.

More Installation Options
HARMONY Elite systems may be wall mounted or floor mounted. With its high/medium ESP outdoor air fan motor the HARMONY ELITE can be installed without ducting on an exterior wall, or with up to 25’ of ducting on an interior wall. With optional equipment the HARMONY ELITE can even be mounted for portable use.

Gravity and Pump-Lift Drainage
Condensate collects in the base pan and drains downward through a connected hose. For systems that are mounted lower than the desired drainage area, a condensate pump may be installed.

Quiet Operation
With an optimized acoustic designed air flow tunnel, anti-leak insulation, a multi-speed fan, and the use of separate indoor and outdoor fan motors, the YMGI HARMONY ELITE System is engineered for comfortable and quiet operation. A random pitch cross-flow fan wheel used on the indoor evaporator coil, eliminates the annoying “air rush” noise. Our compressors are designed for smooth and quiet operation. To further reduce noise, YMGI uses a sound and vibration absorbing insulation jacket around the compressor.

Precise bending and joining of the copper tubing and refrigeration components also reduce tension and vibration. Weight-balancing rubber is then used to further minimize vibration of the refrigeration tubing in extreme operating conditions. Combining all of these features create a system that runs at 22dB at low speeds, and just 38dB at high.

Quality & Reliability

HARMONY ELITE Systems are thoroughly tested under stringent conditions. We construct each unit to ensure many years of trouble free service, and easy maintenance. YMGI stands behind each product with technical support, and warranty coverage.

User-Friendly Comfort & Convenience

Memory and Auto Restart
If your system should lose power, YMGI HARMONY systems remember the operation mode, airflow, and temperature settings and continue normal operation once power is restored.

Digital Display On/Off
Our easy to read LCD display can be turned on or off with the remote control. This feature allows a room to remain dark at night, or you can turn the digital display on and use the display as a night-light

24-Hour On/Off Timer
Set your system to heat or cool any time of day.

Sleep Mode
With the Sleep Mode on, the system will adjust the room target temperature to slowly rise when cooling or fall when heating. Saving energy, and allowing you to sleep comfortably while preventing sudden changes in the room’s temperature.

Auto Mode
By continuously sensing and comparing the set temperature to the room temperature, this feature switches between heating and cooling modes automatically delivering the exact amount of warm or cool air needed to ensure maximum comfort.

Air Swing
Motorized louvers that pivot vertically or horizontally, direct air throughout a room, maintaining an even temperature, and eliminating hot or cold spots. The louver motor can also be turned off, so that you can direct air flow to a specific spot. And it can all be adjusted using the remote control.

Hot Start-Up
When heating operation is selected, or when the system transitions from cooling to heating, the indoor fan motor doesn’t immediately start. This prevents cold air from being blown into an already cold room. When the indoor unit coil and pipes are heated, the fan engages and circulates warm air.

YMGI Technology

Optimized System Design
Components are both individually and systematically optimized to ensure HARMONY ELITE systems work in wide ranges of applications, and deliver the right amount of heating or cooling when you need it, and with maximum efficiency.

Over-Current & Over-Heat
Built-in protection for over-current, over-heat and over-pressure, ensuring safe operation and longevity of components and the unit.

Flexible Control Options
Your YMGI HARMONY ELITE comes with a standard remote control, but can easily be configured to allow use of a wired or wireless thermostat, or network control.

Thermostat and Network Control Ready
Optional Internal control board can be installed allowing your HARMONY ELITE Systems to work with any manufacturer’s wall mounted thermostat.
Controllers can also be added, allowing up to 180 systems to be managed through a single PC interface. More units and properties can be added with additional control boards.

Heating and Cooling Boost
This function boosts cooling or heating capacities at high compressor and fan speed. Rooms reach set temperatures as rapidly as possible.

Environmentally Friendly Inside & Out

Reusable Washable Filter and Advanced Filters

WMMP washable particulate filters contain activated charcoal to help eliminate odors.
WMMP washable particulate filters contain activated charcoal to help eliminate odors.

The YMGI HARMONY ELITE comes with a standard washable particulate filter. We also offer advanced filtration options, such as our active enzyme filter to eliminate bacteria, cold catalyst filter for removing pollen, dust, bacteria and harmful airborne chemicals from carpeting, flooring, paint and household cleaners, and our static electric filter for more thorough dust removal. With our selection of specialized filtration options, you can customize your indoor units to your air quality needs.

Active Carbon and Ionic Filtration
HARMONY ELITE reusable filter contains active carbon to help eliminate smoke, allergens, bacteria and odors. Ionic filtration also helps eliminate the finest particulates.

Easy Filter Cleaning
Filters easily lift from the top of the unit, and are washed with water. Dry thoroughly before reinserting into system.

MODEL NO. WMMS-09K-31A(P4) WMMS-12K-31A(P4) WMMS-09K-32A(P4) WMMS-12K-32A(P4)
THERMAL MODE AC Only Heat Pump
COOLING CAPACITY Rated ID 80/67F OD 95F BTU/H 1), 2) 9000 12000 9000 12000
HEATING CAPACITY Rated ID 70/60F OD 47F (17F) BTU/H 1), 2) N/A N/A 9500(5000) 12800(6800)
ELECTRIC HEATER RATED WATTS N/A N/A N/A N/A
DEHUMIDIFICATION RATED PTS./DAY 42.2 48.6 42.2 48.6
SEER RATED BTU/H.W 13 13 13 13
HSPF RATED BTU/H.W N/A N/A 8.1 8.0
SOUND LEVEL (POWER) INDOOR/OUTDOOR dB(a) 22-23/36-38 22-23/36-38 22-23/36-38 22-23/36-38
REFRIGERANT PRE-CHARGED YES R410A R410A R410A R410A
INPUT POWER SOURCE A: 115/1/60 F: 220/1/50 A: 115/1/60 F: 220/1/50
POWER CONSUMPTION COOLING WATTS 960 1130 960 1130
HEATING WATTS N/A N/A 920 1095
TOTAL CURRENT COOLING AMP 8.9 9.8 8.9 9.8
HEATING AMP N/A N/A 8.0 9.5
MCA FOR WIRE SIZING AMP 15 18 15 18
MINIMUM WIRING SIZE LENGTH OF LESS THAN 15 FT AWG 14 14 14 14
HVAC CIRCUIT BREAKER FOR FUSE SIZING AMP 20 20 20 30
INDOOR FAN MOTOR Fan TYPE CROSS-FLOW CROSS-FLOW CROSS-FLOW CROSS-FLOW
CFM 230/265/300 230/265/300 230/265/300 230/265/300
MOTOR RATED WATTS 14-15 14-15 14-15 14-15
MAX. SPEED 1350 1350 1350 1350
OUTDOOR FAN MOTOR Fan TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL
CFM 1175 1175 1175 1175
MOTOR STYLE PSC PSC PSC PSC
COMPRESSOR HERMETIC BRAND TOSHIBA OR PANASONIC OR HITACHI OR EQUIVALENT
CONTROL THERMOSTAT CONTROL REPLACING PCB OPTIONAL OPTIONAL OPTIONAL OPTIONAL
REMOTE CONTROL INCLUDED Yes Yes Yes Yes
REMOTE CONTROL INCLUDED Yes Yes Yes Yes
LOW AMBIENT CONTROL INCLUDED Yes Yes Yes Yes
DEFROST ON DEMAND INCLUDED Yes Yes Yes Yes
ANTI-ICE INCLUDED ID/OD ID/OD ID/OD ID/OD
CONNECTIONS DRAINAGE DRAIN PIPE 1/2″ID 3/4″OD 1/2″ID 3/4″OD 1/2″ID 3/4″OD 1/2″ID 3/4″OD
WIRES OPEN STRITPED END 3 Ft. 3 Ft. 3 Ft. 3 Ft.
LCD I OPTIONAL OPTIONAL OPTIONAL OPTIONAL
AIR PIPES-ROUND INTAKE / EXHAUST DIA./MAX. FT. 8 INCHES / 25 Ft. 8 INCHES / 25 Ft. 8 INCHES / 25 Ft. 8 INCHES / 25 Ft.
LOUVER-INTAKE / EXHAUST TYPES STANDARD-ROUND PIPE / EXTERIOR. OPTIONAL-ROUND PIPE-RECTANGULAR EXTERIOR
INSTALLATION LIMIT-HIGH (TOP TO GROUND) FT 8 8 8 8
LIMIT-LOW (TOP TO GROUND) FT 0 0 0 0
INSTALLATION KIT AIR-FLOW PIPES INTAKE / EXHAUST 1/1 1/1 1/1 1/1
GRILLES INTAKE / EXHAUST 1/1 1/1 1/1 1/1
WORKING AMBIENT TEMPERATION RANGES (AC / HP) °F 45-104 / NA 45 to 104 / 35 to 80
WEIGHT NET LBs 104 106 104 106
GROSS LBs 112 118 112 118
DIMENSION WxHxD UNIT INCH 37 x 24 x 10 37 x 24 x 10 37 x 24 x 10 37 x 24 x 10
BOX INCH 39 x 26 x 12 39 x 26 x 12 39 x 26 x 12 39 x 26 x 12
MODEL NO. WMMS-09K-34A(P4) WMMS-12K-34A(P4) WMMS-09K-34B(P4) WMMS-12K-34B(P4)
THERMAL MODE Heat Pump+Aux Heater HP+Back Up Heater
COOLING CAPACITY Rated ID 80/67F OD 95F BTU/H 1), 2) 9000 12000 9000 12000
HEATING CAPACITY Rated ID 70/60F OD 47F (17F) BTU/H 1), 2) 9500(5000) 12800(6800) 9500(5000) 12800(6800)
ELECTRIC HEATER RATED WATTS 1500-1800 1500-1800 2400-3000 2400-3000
DEHUMIDIFICATION RATED PTS./DAY 42.2 48.6 42.2 48.6
SEER RATED BTU/H.W 13 13 13 13
HSPF RATED BTU/H.W 8.1 8.0 8.1 8.0
SOUND LEVEL (POWER) INDOOR/OUTDOOR dB(a) 22-23/36-38 22-23/36-38 22-23/36-38 22-23/36-38
REFRIGERANT PRE-CHARGED YES R410A R410A R410A R410A
INPUT POWER SOURCE A: 115/1/60 F: 220/1/50 B: 208-230/1/60 F: 220/1/50
POWER CONSUMPTION COOLING WATTS 960 1130 960 1130
HEATING WATTS 920 1095 920 1095
TOTAL CURRENT COOLING AMP 8.9 9.8 8.9 9.8
HEATING AMP 8.0+5.0 9.5+5.0 4+10.4 4.7+13.0
MCA FOR WIRE SIZING AMP 20 20 20 20
MINIMUM WIRING SIZE LENGTH OF LESS THAN 15 FT AWG 12 12 12 12
HVAC CIRCUIT BREAKER FOR FUSE SIZING AMP 30 30 30 30
INDOOR FAN MOTOR Fan TYPE CROSS-FLOW CROSS-FLOW CROSS-FLOW CROSS-FLOW
CFM 230/265/300 230/265/300 230/265/300 230/265/300
MOTOR RATED WATTS 14-15 14-15 14-15 14-15
MAX. SPEED 1350 1350 1350 1350
OUTDOOR FAN MOTOR Fan TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL
CFM 1175 1175 1175 1175
MOTOR STYLE PSC PSC PSC PSC
COMPRESSOR HERMETIC BRAND TOSHIBA OR PANASONIC OR HITACHI OR EQUIVALENT
CONTROL THERMOSTAT CONTROL REPLACING PCB OPTIONAL OPTIONAL OPTIONAL OPTIONAL
REMOTE CONTROL INCLUDED Yes Yes Yes Yes
REMOTE CONTROL INCLUDED Yes Yes Yes Yes
LOW AMBIENT CONTROL INCLUDED Yes Yes Yes Yes
DEFROST ON DEMAND INCLUDED Yes Yes Yes Yes
ANTI-ICE INCLUDED ID/OD ID/OD ID/OD ID/OD
CONNECTIONS DRAINAGE DRAIN PIPE 1/2″ID 3/4″OD 1/2″ID 3/4″OD 1/2″ID 3/4″OD 1/2″ID 3/4″OD
WIRES OPEN STRITPED END 3 Ft. 3 Ft. 3 Ft. 3 Ft.
LCD I OPTIONAL OPTIONAL OPTIONAL OPTIONAL
AIR PIPES-ROUND INTAKE / EXHAUST DIA./MAX. FT. 8 INCHES / 25 Ft. 8 INCHES / 25 Ft. 8 INCHES / 25 Ft. 8 INCHES / 25 Ft.
LOUVER-INTAKE / EXHAUST TYPES STANDARD-ROUND PIPE / EXTERIOR. OPTIONAL-ROUND PIPE-RECTANGULAR EXTERIOR
INSTALLATION LIMIT-HIGH (TOP TO GROUND) FT 8 8 8 8
LIMIT-LOW (TOP TO GROUND) FT 0 0 0 0
INSTALLATION KIT AIR-FLOW PIPES INTAKE / EXHAUST 1/1 1/1 1/1 1/1
GRILLES INTAKE / EXHAUST 1/1 1/1 1/1 1/1
WORKING AMBIENT TEMPERATION RANGES (AC / HP) °F 45 to 104 / 35 to 80 45 to 104 / 35 to 80
WEIGHT NET LBs 104 106 104 106
GROSS LBs 112 118 112 118
DIMENSION WxHxD UNIT INCH 37 x 24 x 10 37 x 24 x 10 37 x 24 x 10 37 x 24 x 10
BOX INCH 39 x 26 x 12 39 x 26 x 12 39 x 26 x 12 39 x 26 x 12